img001 Extract from a report on the condition of the distribution box and cut-out on vehicle 18-CIV after 10,000 miles.
View original record X6067 Extract from report on 18-CIV at 10,000 miles dated 30.1.31. X.6067 X.5740 DISTRIBUTION BOX AND CUT-OUT TO LOP.D.51907. The distribution box remained in good condition. The cut-out has operated…

img002 Reference sheet for previous information regarding the 40/50 distribution box and cut-out.
View original record X.6068. 1.1.31. For previous matter relating to 40/50 distribution box and cut-out (general) see X.7740.

img003 Cover letter for specification pages regarding the R.R. Distribution Box and Cutout for Phantom II and 20/25 models.
View original record X6068 By. from Hs/Pgt. c. Sft/Mr.Brock. Hs/Pgt.1/AM6.10.31. X.6088 R.R. DISTRIBUTION BOX AND CUTOUT X.6016 X.6087 PHANTOM II AND 20/25. X.6067 X.6068 We attach herewith pages 1 and 3 of Specification…

img004 Specification for production inspection, adjustment, and testing of a distribution box and cutout for 40/50 and 20/25 HP cars.
View original record 16.10.31. R.R. DISTRIBUTION BOX AND CUTOUT. Type for use on 40/50 and 20/25 HP. cars in conjunction with two-rate charge scheme. SPECIFICATION OF PRODUCTION INSPECTION. ADJUSTMENT AND TEST. (1) The…

img005 Test procedure for a dynamo and distribution box, detailing voltage, amperage, and resistance limits.
View original record -2- dynamo, a 12 volt battery of suitable capacity, two ammeters A and B, and two voltmeters V and v, according to diagram herewith, the latter voltmeter having a loose lead suitable for touching on…

img006 Instructions for testing the point at which dynamo cutout contacts separate.
View original record -3- (6) The dynamo speed shall be reduced until the ammeter A reading is zero. The connections to this ammeter shall then be reversed, after which the speed shall gradually be reduced still further…

img007 Wiring diagram for a 40/50 distribution box and cutout test.
View original record CONNECTIONS FOR R.R. 40/50 DISTRIBUTION BOX & CUTOUT TEST R A V B A F + -

img008 Redesign of the distribution board and cut-out unit for various chassis models.
View original record X6067 To R. from Hs/Wst. c. to Sg. -Wor. c. to E. Da. c. to By. Hs/Wst.2/KT.4.11.31. X6067 X6068 DISTRIBUTION BOARD & CUT-OUT. We consider that this unit could be very profitably redesigned for both…

img009 Recommendation to relocate the dynamo cut-out and consolidate the electrical circuit distribution for the 20/25 chassis.
View original record HS/Wst.2/CL.4.11.31.cont'd. -2- This extra space on the 20/25 will also be still further required when this chassis is equipped with a relay operated starter. Our recommendation therefore, is to…

img010 Electrical experimental record sheet for a 20/25 Switchbox.
View original record X. No. X6067 Item No. ELECTRICAL EXPERIMENTAL RECORD SHEET. Description of item :- 20/25 Switchbox - T-R S+T cum first. 2J resistance Date on | Location | REMARKS | Miles reading start | Miles…

img011 Consolidation of the electrical distribution system and the provision of an accessory distribution box for body wiring.
View original record To E. from Hs/Wst. c. Ev-Sg. Hor. [crossed out text] X6067 Hs/Wst.5/AM 9.1.32. BODY WIRING AND ACCESSORY BOXES. X6068 Referring to El/M18.1.32, our views are that the whole of the distribution system…

img012 Body wiring and accessory box for the Phantom II chassis.
View original record X6068 WST F. Sg. G. Wcn. c. Hs. C. Da. BY/Cgh.6/G. 22.1.32. RE: PHANTOM 11 CHASSIS. BODY WIRING AND ACCESSORY BOX. With reference to E.1/M.18.1.32. we are of the same opinion as the Experimental…

img013 The body wiring for the Phantom II chassis, specifically regarding the high prevalence of electric cigar lighters.
View original record WST X6068 HS S/W to BY (C. Sg. E. Wor, Hs, DA. Hn) re- Phantom II Chassis Body Wiring and Accessory Box. With regard to paragraph 3 of BY/Cgh.6/G22.1.32, we estimate that something like 80 to 90 per…

img014 The update of the instrument board on chassis 18-G-IV and 19-G-IV.
View original record X6067. C - Hs/Lid. BY/RD1/W.4-2-32. Re :- Chassis 18-G-IV and 19-G-IV. These two chassis are having Smith's Instrument Patches, and in order to bring the Instrument Board up to date, the latest type…

img015 Standardisation of a distribution board and cutout to D.54343.
View original record RR 7881 (SH) (57394. 30-1-34) BM 3/787/1. COMPLETED 20.9.34! 20/25 STANDARDISATION of PARTS. Description of Parts. DISTRIBUTION BOARD AND CUTOUT TO D.54343. Origin. TO SUIT VOLTAGE CONTROLLED DYNAMO…

img016 List of blueprints for new parts related to the 'Spectre' Distribution Board, R.R.Sch.723.
View original record RHC c. Hs/Wst. 16067 BY/RD2/W.23.11.34. "Spectre". Distribution Board, R.R.Sch.723. -Please receive herewith blue prints of the following new pieces,detailed from the above scheme :- D.54563. Spring…

img017 Modifications to fuse clip holders for the 'Spectre' Distribution Board, R.R. Scheme 723.
View original record RHC C.B. c. Hs/Wst. BY/RD4/W.2.1.35. "Spectre" Distribution Board. R.R.Scheme 723. With reference to the sample fuse clip holders supplied to E., these have now been examined and one particular type…

img018 Request to detail the Phantom III distribution box D.CD.59 for trial, with a note about fitting new type fuses.
View original record De/RD. c. Rm. o. TR. 6064, DA.1/G.10.9.37. PHAN. 111 - DISTRIBUTION BOX. Will you please detail and instruct D.CD.59, which is agreed to for trial and for submission to criticism. New type fuses to be…

img019 The Bentley Chassis Distribution Board in relation to a revised instrument board for chassis B.56.BN.
View original record To HPS. c. Rm/RC. 6067. Re BY/RD.2/B.14.9.37. Bentley Chassis Distribution Board - Sec.8170. In conjunction with the revised instrument board which is being fitted to B.56.BN., we send you herewith,…

img020 Approval for detailing the Wraith III electrical system's 5 fuse distribution box and regulator unit.
View original record RCC DA/HD c. Rm. 5092, 6068? DA.4/G.16.9.37. WRAITH 111 - ELECTRICAL SYSTEM. D.CD.70/71 respectively 5 Fuse Distribution box and modified cutout and regulator unit, have been approved for detailing,…

img021 Production and mounting of a Phantom III Distribution Board.
View original record 6067, To HPG. c.c. Rm/RC. c.c. BY/HBB. BY/RD.3/B.21.9.37. "Phantom III" Distribution Board. Sec.8170. D.CD.59. Will you please put in hand a Distribution Board for 39.EX to LOP. D. 76120. Blueprints…

img022 Technical memo detailing the revised position of the distribution board for the 'Phantom III'.
View original record To HPS. c. Rm/RC. cr. BY/HLB. 6067 BY/RD.1/B.1.10.37. "Phantom III" - Revised Position of Distribution Board. D.CD.59. In conjunction with the new type distribution board instructed in our memo'…

img023 Continued list of standard parts, quantities, and their alternatives.
View original record -2- BY/RD.1/B.1.10.37 Sec.7360 - Standard parts not required )Cont'd). D.75362 - Conduit - Footswitch. 1 off. K.112A - 2 BA. Bolt. ) KA.112A - 2 BA. Bolt. ) Alternatives. 2 off. K.113A - 2 BA. Bolt. )…

img024 Instruction to issue a new open type fuse and base for the Wraith III distribution board on the experimental chassis.
View original record 6067. To HPS. c. BY. c. Rm/RC. c. RHC/CAN. BY/RD.2/B.22.10.37. Wraith III - Distribution Board. In order that this Distribution Board may have the open type fuse upon it, we are issuing herewith, the…

img025 Proposal for an alternative fuse design to replace unreliable cartridge fuses on the Phantom III and Bentley Chassis distribution board.
View original record 6067. To HPB, c.c. BY, c. Rm/RC. c.c. RHC/CAN. RC BY/RD.2/B.10.12.37. Phantom III and Bentley Chassis. Distribution Board - Sec.8170. Owing to the constant unreliability of the cartridge type fuse, it…

img026 Requesting the production of a 5-fuse distribution board for Wraith Experimental cars.
View original record c. Fm/RC. 6067. BY/RD.1/E.5.1.38. 5 FUSE DISTRIBUTION BOARD - D.CD.70 & D.CD.266. Will you please put in hand for Wraith Experimental cars, excluding the first six which have a temporary distribution…

img027 Modification to a 5-fuse distribution board.
View original record BY/NOV. c. Rm. -------- CHILDS 6067. Da.9/G.5.1.38. MODIFIED 5 FUSE DISTRIBUTION BOARD. It is probable that the switchbox will be simplified and its "Master Switch" feature (complete isolation of the…

img028 Modifications to the Wraith III distribution board and associated blueprints.
View original record 6067 RC To. HPS. c. BY. c. RHC/CAN. c. HPS/RH. C.c. Roy/Ms. (16.2.38). C.c. RHC. c. C/H. c. Rm/Grys. BY/RD.2/B.11.2.38. WRAITH III. (6 SETS). Distribution Board - Sec.8170. We hand you herewith…

img029 Modification to the fuse contact on the distribution board for all chassis.
View original record cap. 6067 To HPS. c.c. BY/RD. c.c. Rm/RC. c.c. RHO/Wld. c.c. RHC/SS. c.c. Roy/Lee. for HPS. BY/RD.9/B.21.3.39. ALL CHASSIS. DISTRIBUTION BOARD. SECTION 8170. Please receive herewith, blueprints of :-…

img030 The production and experimental fitting of 24 newly designed DB.2342 Fuse Contacts for distribution boards.
View original record 6067 To RH. from HPS/WSC. To. Rm/RC. HPS/WSC.7/BA.21.4.39. 0/52440. Distribution Boards - All Chassis. We have now produced 24 - DB.2342 Fuse Contacts being different from standard by being produced…

img031 The issue of a covering order to Messrs. Lucas Ltd. for one DKH4.0 Distributor.
View original record 6067 To Roy/AES. from Rm/RC. Rm/RC.2/ET.12.3.41. Will you please issue a covering order to Messrs. Lucas Ltd., for 1 - DKH4.0 Distributor, as per the attached advice note No. SLD.23090. O/N. 773.…

img032 Letter from Joseph Lucas Ltd. regarding a sample 5-way Fuse Box of the 5ML Model and an enclosed drawing.
View original record JOSEPH LUCAS LTD. "KING OF THE ROAD" ACCESSORIES GREAT KING STREET BIRMINGHAM, 19. TELEPHONE : NORTHERN 5201 TELEGRAMS & CABLES: "LUCAS, TELEX, BIRMINGHAM" WHEN REPLYING PLEASE REFER TO X/BGC/HA. 20th…

img033 Letter from Joseph Lucas Ltd. about a previously omitted drawing for a C.A.V. 5ML Model Fuse Box.
View original record JOSEPH LUCAS LTD. "KING OF THE ROAD" ACCESSORIES GREAT KING STREET BIRMINGHAM. 19. TELEPHONE : NORTHERN 5201 TELEGRAMS & CABLES : "LUCAS. TELEX. BIRMINGHAM" EN REPLYING PLEASE REFER TO X/BGC/HA. 6067…

img034 Covering order for a UF62/1160 type fuse box from Messrs. Lucas.
View original record Rm/RC 6067 To Roy/AES. from Rm/RC. Rm/RC.1/ET.24.10.41. Will you please issue a covering order to Messrs. Lucas for 1 - UF62/1160 type fuse box. This box is now in our possession. O/N.753. Rm/RC.

img035 Covering order for one Lucas type fuse box.
View original record 6067 To Roy/AES. from Rm/RC. Rm/RC.1/ET.24.10.41. Will you please issue a covering order to Messrs. Lucas for 1 - UF62/1160 type fuse box. This box is now in our possession. O/N.753. Rm/RC.

img036 Letter to Joseph Lucas, Ltd. concerning a fuse box and requesting three pairs of standard Bentley type headlamps.
View original record Elec 6067 Rm/RC.6/ET. 24th October, 1941. Messrs. Joseph Lucas, Ltd., Great King Street, BIRMINGHAM, 9. Attention of Mr. B.G. Cropper. Dear Sirs, We thank you for your letter of 20th and 21st October…