Troubleshooting guide for a shock damper system, outlining potential causes and inspection points.


Identifier  ExFiles\Box 178\1\  img171
Date  22th June 1926
  
- 16 -

Hs {Lord Ernest Hives - Chair} /Rml/T22.6.26.

(i) Air has got into the system. In this case passage C should be inspected to see that this is not blocked up.

(ii) The supply valves L are not working correctly. These should be inspected to see that the balls have free movement.

In the event of the shock damper load changing appreciably, the valves L should again be inspected, and also filter O to see that this is not blocked up. Too low an oil level in the damper may also be responsible for these troubles.


Hs {Lord Ernest Hives - Chair} /W.A. Robotham.
  
  