Particulars of the winding and commutator setting for intermediate output armatures for 20 HP and 40/50 HP dynamos.


Identifier  ExFiles\Box 60\1\  Scan102
Date  7th April 1929
  
To BY. {R.W. Bailey - Chief Engineer} from EFC. {E. Fowler Clarke - Electrical Engineer}
c. BY {R.W. Bailey - Chief Engineer} /RD.

X6004
EFC {E. Fowler Clarke - Electrical Engineer} 1/T17.4.29.

INTERMEDIATE OUTPUT ARMATURES.

Further to our EFC {E. Fowler Clarke - Electrical Engineer} 4/LG21.2.29, we now give further particulars of the winding and commutator setting of these two 24 slot intermediate output armatures for the 20 H.P. and 40/50 H.P. dynamos:-

Armature:- 24/48/4.

No. of slots or sections. 24
No. of coils or comm. bars 48
No. of conductors to comm. 96
No. of conductors. 384

Coils per slot. 2
Turns per coil. 4
Conductors per slot. 16

Slot pitch of coils 1 to 6
" " (comm.end) 1 to 7&8
Comm. bar pitch. 1-25-48

M angle for 20 H.P. 48.0°
M angle for 40/50 H.P. 46.5°


EFC. {E. Fowler Clarke - Electrical Engineer}
  
  