Test results for J.III type shock dampers with a conical seated valve and damping 'hat'.


Identifier  ExFiles\Box 56\1\  Scan222
Date  4th October 1932
  
COPY FOR FILES. X235 4.10.32.

J.III TYPE SHOCK DAMPERS. X5520

N.S.3497 CONICAL SEATED VALVE WITH Hs. {Lord Ernest Hives - Chair} 712 VALVE

DAMPING "HAT".

The following were found to give the best
results, when the valve was set definitely on its
seat :-

(a) With .005" diametral "hat" clearance, two
holes .055" diam were required in the wall
of the "hat".

(b) With a .032" diam hole in the L.P. face of
the valve, and .015" diametral clearance,
two holes .093" diam were required in the
wall of the "hat".

In the case of the former there was a
slight tendency to squawk when starting from cold,
but there was no building up of static load after
recooling; a slight valve knock occurred at approx
1.5 ft/sec mean axle velocity.

With the latter setting there was no squawk
and no building up of static load, but there was
a tendency to knock above a mean axle velocity of
1 ft/sec.

When using a .032" diam hole in the L.P.
valve face it was found necessary to increase the
diametral clearance to .050" when the holes in the
"hat" wall were deleted, even then there was an
increase of static load on recooling of 25-30%.

Under both the above condition (a & b)
the static load decreased from 90 to 75 lb at a
temperature of approx 60°C, but returned to 90 lb.
when recooled.


Hs {Lord Ernest Hives - Chair} /W.Bell.
  
  