Rolls-Royce Archives
         « Prev  Box Series  Next »        

Water circulation test graphs for PII, comparing pump delivery against water temperature for different radiator configurations.


Identifier  ExFiles\Box 15\1\  Scan303
Date  1st July 1930 guessed
  
WATER CIRCULATION TESTS PII

Graph 1:
- Y-Axis: PUMP DELIVERY GAL/MIN
- X-Axis: BOTTOM WATER TEMP °C
- Line 1: RAD E.79321, BOTH SUCTION OUTLETS IN USE
- Line 2: 1st L.H. CHASSIS, RAD WITH THERMOSTAT E.77675
- Note: 2500 ENGINE R.P.M.

Diagram 1 (Top Right):
- Rad E79321
- 6 3/16" & 7 9/16"
- 26 5/8"
- 4 DEEP
- 23 5/8"

Diagram 2 (Bottom Right):
- Rad E.77675
- 6 3/16" & 7 9/16"
- 26"
- 4 DEEP
- 23.25"

Graph 2:
- Title: S.S. UNIT S.S.7, RAD E.79321 VENTURI IN OUTLET
- Left Y-Axis: WATER PUMP DELIVERY GAL/MIN
- Right Y-Axis: PUMP SUCTION DEPRESSION INS H₂O
- X-Axis: BOTTOM WATER TEMP °C
- Line 1: DEPN ON SUCTION SIDE OF PUMP
- Line 2: FLOW GAL/MIN
- Line 3: PUMP INLET DEPN
- Note: 2500 ENGINE R.P.M.
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).