Comparison of Rover and Wilmot stabilisers, noting frequency and damping characteristics.


Identifier  ExFiles\Box 3\6\  06-page271
Date  20th October 1934
  
-3-

Hm {Capt. W. Hallam - Head Repairs} /PJL.4/KW.20.10.34.

In the case of the Rover Stabiliser, the difference in frequency between the loose and tight conditions is of the order of 100/min.

The effect of the tightness of these nuts upon the damping and frequency is a bad feature of the design.

The curves for the Wilmot Stabiliser show that from a frequency of 670/min. to 800/min. the frame amplitude is constant, whereas that of the lamps increase by 100%. This indicates that the lamps must be moving relative to the frame. This movement is probably due to twisting of the individual side members of the frame.

Hm {Capt. W. Hallam - Head Repairs} /F.J.Hardy.
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).


Copyright Sustain 2026, All Rights Reserved.    whatever is rightly done, however humble, is noble