Rolls-Royce Archives
         « Prev  Box Series  Next »        

Battery charging tests, detailing charge cycles, cell densities, and temperatures.


Identifier  ExFiles\Box 54\1\  Scan181
Date  1st July 1925
  
-3-

(13) Third charge equivalent to average current of 6.0 amperes
for 16.5 hours.
i.e. ampere-hours = 99.0

(14) Cell densities.
(1) 1280 (4) 1250
(2) 1250 (5) 1280
(3) 1280 (6) 1250

(15) Initial amperes = 103 Temp :- 18°C 64°F. {Mr Friese}

[Handwritten note on left]
Ex-1.5 voltages of
P&R 1.45 each cell on
Box 1.0 discharge
P&R 1.6 when at 20.0
Box 1.25 amperes.
P&R 1.25.

Time to 104 amperes:- mins.
" " 100 " : 6.4 "
" " 90 " : 14.6 "
" " 80 " : 16.7 "

(16) Fourth charge equivalent to average current of 6.0 amperes
for 17.0 hours.
i.e. ampere-hours = 102.0

(17) Ampere hours realised up to a point where record takes a sudden turn down :- 61.8.
Temperature :- 19°C 66°F. {Mr Friese}

(18) Fifth charge equivalent to average current of <strikethrough>amperes</strikethrough> 6.0 amperes
for 16.5 hours
i.e. ampere-hours :- 99.0

-------------------

[Right column]
Date.
1-7-25 to
2-7-25.
3-7-25.
3-7-25.
3-7-25 to
6-7-25.
7-7-25.
8-7-25 to
9-7-25
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).


Copyright Sustain 2026, All Rights Reserved.    whatever is rightly done, however humble, is noble