Rolls-Royce Archives
         « Prev  Box Series  Next »        

Performance comparison of different types of radiator tubes tested on a 19EX car at Brooklands track.


Identifier  WestWitteringFiles\U\August1930-November1930\  Scan119
Date  14th October 1930 guessed
  
FIGURES GIVEN ARE CRITICAL ATS TEMP AT WHICH THE CAR WILL EVENTUALLY BOIL IF DRIVEN SUFFICIENTLY LONG
DETAILS OF RADIATORS

TABLE DATA:

COLUMN HEADERS:
- TYPE OF RADIATOR TUBES
- 60 M.P.H NO BONNET VENTILATION (TEMPS CENTIGRADE)
- ALL OUT NO BONNET VENTILATION (DEGREES)
- ALL OUT VERTICAL LOUVRED BONNET
- RADIATOR WT LBS EMPTY
- RADIATOR WT LBS FULL
- NO OF TUBES
- SQ.FT SURFACE OF RADIATOR
- % DIRECT COOLING

ROW 1:
- Type: LATEST E 81385 6m.m. SQUARE PARALLEL TUBES
- Temps Centigrade: 42
- Degrees (No Bonnet): 33
- Degrees (Louvred Bonnet): 39.75
- Wt Empty (LBS): 140
- Wt Full (LBS): 176*
- No of Tubes: 8860
- Surface (SQ.FT): 218.5
- % Direct Cooling: 46.2

ROW 2:
- Type: STANDARD. 6/7 1/2 TURBULENT AIRFLOW TUBES
- Temps Centigrade: 39.5
- Degrees (No Bonnet): 30.5
- Degrees (Louvred Bonnet): 39
- Wt Empty (LBS): 120.5
- Wt Full (LBS): 168
- No of Tubes: 8115
- Surface (SQ.FT): 164
- % Direct Cooling: 84.4

ROW 3:
- Type: 6/7. EXPANDED END SQUARE TUBE. E80239
- Temps Centigrade: 37.75
- Degrees (No Bonnet): 28.0
- Degrees (Louvred Bonnet): 36.75
- Wt Empty (LBS): 132
- Wt Full (LBS): 173*
- No of Tubes: 7050
- Surface (SQ.FT): 178
- % Direct Cooling: 84.5

ROW 4:
- Type: 5 1/2 / 7 ROUND TUBES E79321
- Temps Centigrade: 36.75
- Degrees (No Bonnet): 24.75
- Degrees (Louvred Bonnet): 34.75
- Wt Empty (LBS): 137.75
- Wt Full (LBS): 181
- No of Tubes: 8991
- Surface (SQ.FT): 163.5
- % Direct Cooling: 84.3

ROW 5:
- Type: GALLAY. ZIG ZAG RIBBON NO INDIRECT
- Temps Centigrade: 34.5
- Degrees (No Bonnet): 25.0
- Degrees (Louvred Bonnet): Not Taken.
- Wt Empty (LBS): 114
- Wt Full (LBS): 154
- No of Tubes: Not Calculated
- Surface (SQ.FT): Not Calculated
- % Direct Cooling: 84

ROW 6:
- Type: STANDARD 6/7 1/2 TUBES E79448
- Temps Centigrade: 34.25
- Degrees (No Bonnet): 21.75
- Degrees (Louvred Bonnet): 32.25
- Wt Empty (LBS): 120.5
- Wt Full (LBS): 168.5
- No of Tubes: 8115
- Surface (SQ.FT): 164
- % Direct Cooling: 84.4

NOTES:
* SOLID VERTICAL STRIPS. ROLLED VERTICAL STRIPS REDUCE RADIATOR WT BY .15-16 LBS

TESTS CONDUCTED ON 19E.X. CAR ON BROOKLANDS TRACK All RADIATOR MATRIX DIMENSIONS 25.9" x 23.7". CAR WT. 48 CWT AXLE RATIO 11x41.
  
  