The comparative strength and durability tests of various pivot designs and the potential influence of heat treatment.


Identifier  ExFiles\Box 2\12\  B002_X168-page220
Date  7th January 1914
  
J. {Mr Johnson W.M.}
for
R. {Sir Henry Royce}

7.1.14. De7/96114 Cont. -2-

did not make this section weaker than the U, or
appreciably affect its strength.

In tests over obstacles AV/EH2/117313,
and Woz/Ry1/L5713, and F.3253 type pivot ran 540
minutes and then broke in the U, but F.3372 ran
for 1810 minutes and shewed no signs of breaking,
not even being out of truth.

Against this must be set the frame
bumping tests, where a F.3253 pivot stood for
12 hrs. 37 mins. and then broke in the U, while
F.3372 did 6 hrs. 3 mins. and F.3697/8 (the same
as F.3372 but 1/4" shorter in the stub) 7 hrs. 57 mins
12 hrs. 47 mins. and 15 hrs. 32 mins.

These results are somewhat contradictory,
and seem to point to heat treatment or steel as
something to do with it.

The heat treatment employed by Vickers
(the pivots are not treated here) is 800 C and
550 C, the same as you recommend.