Test results table for various Lucas cut-out devices under cold operating conditions.


Identifier  ExFiles\Box 36\4\  scan 042
Date  30th April 1920
  
X.3770. LUCAS CUT-OUT. X.1627.

TEST TABLES.

Cut-out number. | Cold condition Just operated at (volts, amperes) | Cold condition Just de-operated at (volts, Shunt amps, Series reverse amperes.) | Shunt Ohms. (cold) | Remarks.

19 | 12.45 | .27 | 12.45 | .265 | .1 | 46.2 | Passes.
29 | 9.8 | .225 | 11.7 | .27 | 4.4 | 43.4 | Cuts in too early and takes too much reverse current.
91 | 14.1 | .28 | 12.1 | .24 | 1.55 | 50.3 | Cuts in too late.
129 | 10.2 | .20 | 11.9 | .235 | 3.55 | 50.3 | As for 29.
14267 | 11.4 | .22 | 11.9 | .23 | 1.7 | 51.8 | Cuts in slightly too early.
15770 | 13.4 | .30 | 11.8 | .28 | 1.15 | 43.9 | Cuts in slightly too late.
  
  