Rolls-Royce Archives
         « Prev  Box Series  Next »        

Test results for a 3-year-old P&R RR11-3 battery detailing its low and high-rate discharge performance.


Identifier  ExFiles\Box 54\1\  Scan161
Date  30th September 1929
  
E.J.C.
J.D.30.
X4617 P.
30-9-29.
X4617P.
Re Tests on P&R RR11-3 Battery (1&2)
This battery is now 3 years old & has been on our bench life test 34 months & has also ran 3,977 miles on the road.
On Low Rate Discharge through a constant external resistance of 1.80 ω
85.7 ampere hours were obtained, all cells showing positive weakness.
On High Rate Discharge
Initial amperes = 112.0
Time to 104 " = 20.0 min.
All cells showing negative weakness
These results are excellent considering the battery so old as 3 years.
G.J.
  
  