Rolls-Royce Archives
         « Prev  Box Series  Next »        

Comparison of frontal area, weight, and total savings for three different radiator matrix designs.


Identifier  ExFiles\Box 87\1\  scan0136
Date  19th January 1935
  
+40
19.1.35.

(1) Frontal area of standard matrix - 471 sq.in.
(2) " " " N.Sch.4235 " - 396 " "
(3) " " " shortened expt. Matrix - 356 " "

(1) Weight of standard shape matrix in Harrison Vee 31.5 29 lbs.
(2) Estimated weight of N.Sch.4235 shape matrix in Harrison Vee 24.4 28.25 .
(3) " " " shortened exp. matrix in Harrison Vee 22 25 lbs.

Weight of water in (1) 13.75 lbs.
" " " (2) 11.50 "
" " " (3) 10.40 "

Total saving over standard radiator with (1) - 13.0 15.3 lbs.
" " " " (2) - 18.0 22.1 lbs.
" " " " (3) - 22.5 25.6 lbs.

Hs {Lord Ernest Hives - Chair} /Std.
  
  