Corona discharge issue found during an open-circuit test on a Wraith Type Coil, recommending a smaller insert for better clearance.
| Identifier | ExFiles\Box 164\5\ img320 | |
| Date | 15th November 1937 | |
| BY. {R.W. Bailey - Chief Engineer} BY {R.W. Bailey - Chief Engineer} /RD. 6017 Rm {William Robotham - Chief Engineer} /RC. {R. Childs} 9/JH.15.11.37. re Wraith Type Coil. During an open-circuit test on one of the latest type coils, a corona discharge was noticed between the primary terminal insert and the base of the H.T. lead-in. Other coils with similar type case, but with smaller inserts were tried, and it was found that this effect was not nearly so noticeable. From this we recommend that a smaller insert should be used, giving as much clearance as possible between itself and the base of the H.T. lead-in. Rm {William Robotham - Chief Engineer} /RC. {R. Childs} | ||