Rolls-Royce Archives
         « Prev  Box Series  Next »        

From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Table showing the relative viscosity of aqueous glycerol solutions compared with water at various temperatures.

Identifier  ExFiles\Box 151\3\  scan0062
Date  19th October 1928 guessed
  
Relative viscosity of aqueous glycerol solutions as compared with water
Temperature °C.

Glycerin Strength by Weight. 1° 10° 15° 20° 30° 40° 50° 60° 70° 80°
10% 1.366 1.344 1.331 1.321 1.275 1.274 1.272 1.216 1.212 1.189
20% 1.902 1.876 1.857 1.834 1.753 1.636 1.598 1.518 1.462 1.445
30% 2.643 2.603 2.558 2.503 2.358 2.210 2.086 1.994 1.875 1.835
40% 4.320 4.175 4.023 3.858 3.516 3.198 2.958 2.620 2.495 2.342
50% 7.195 6.775 6.256 5.892 5.190 4.621 4.190 3.835 3.466 3.339
60% 13.150 12.27 11.20 10.28 8.807 7.568 6.712 5.904 5.359 5.064
70% 34.230 30.82 26.90 24.11 18.42 14.19 12.14 10.14 8.742 7.801
80% 100.380 88.46 74.23 63.31 43.67 30.75 24.20 19.41 15.96 11.46
85% 190.400 154.4 144.2 99.05 66.84 47.97 35.36 27.60 21.06 17.52
88% 274.600 230.5 181.3 145.8 99.63 68.10 46.77 35.50 26.48 21.32
90% 419.40 324.9 254.3 194.3 123.5 86.46 61.60 43.81 32.08 25.25
92% freezes 473.3 374.1 283.0 186.4 110.4 77.24 56.50 39.42 30.64

The data in the above Table for 1° C. were obtained by us, and the remainder are abstracted from
Z. Oel- u.Fett-Ind., 1925,401.
  
  