Performance comparison and post-test condition report for three different pump types.

Identifier  ExFiles\Box 149\3\  scan0154
Date  24th October 1940 guessed
  
- 4 -

Standard Merlin. Pesco Merlin. Fluid Transfer.

Max. speed (r.p.m.) 2160 2160 2400
(Delivery at 1560 r.p.m.(pts/hr)
((Unrestricted suction and delivery) 2650 2880 3350
Weight. 8lb-6oz. 7lb.0 oz. 5lb.13oz.
Ratio Delivery/Weight at 1560 r.p.m. 316 412 576
(Speed at which pumping commences
( (r.p.m.)
((2ft. suction lift and unrestricted delivery) 100 - 125
Power required to drive pump at 1560 r.p.m. (H.P.) .6 - .1
Method of lubrication. Fuel Lubricated Fuel Lubricated Fuel Lubricated.

Condition of Pump After Test.

Following these tests the oscillating plate (in aluminium alloy) showed signs of bad pick-up on the pump casing (also in aluminium alloy) suggesting that alternative and probably heavier material would be necessary here.

Otherwise the condition of the pump was good.

General Conclusions.

As front page.