Graph plotting logarithmic temperature against distance and time to compare cooling performance with various fan, shutter, and louvre configurations.
Identifier | ExFiles\Box 24\4\ Scan290 | |
Date | 26th November 1924 guessed | |
23 3/4 MATRIX 30 M.P.H. NO FAN STANDARD SHUTTERS OPEN LOUVRES OPEN a = .0990 a = .1445 a = .1540 a = .1660 TO CORRECT FOR FRICTION HEAT, THESE READINGS MUST BE MULTIPLIED BY 1.225 NO FAN COOLING DECREASED 32% SHUTTERS COOLING INCREASED 7% LOUVRES COOLING INCREASED 14% A LATER TEST SHOWS THIS TO BE HIGH Graph Labels: NO FAN STANDARD SHUTTERS LOUVRES Axis Labels: LOG θ DISTANCE TIME | ||