Laboratory report comparing an unused and a used sample of 'Castrol' Oil.

Identifier  ExFiles\Box 32\3\  Scan070
Date  2nd February 1925 guessed
  
Hs.{Lord Ernest Hives - Chair} for attention of Mr Warwick.
X1583
H11/EF19824.
Laboratory.
Re 2 samples of "Castrol" Oil. No.1-unused, No. 2---used.
Sample 1.
Flash Point 225°C.
Moisture 0.74%
Acid 0.62%
Sample 2.
185°C.
0.47%
0.89%
The Fatty Acid is higher than usual, and this percentage in the presence of the moisture would tend to cause corrosion.
The low Flash Point of the used castrol oil indicates the presence of about 0.10% Petrol.