Rolls-Royce Archives
         « Prev  Box Series  Next »        

Graph showing test results for the effect of short circuit secondary turns on a coil under different loads.


Identifier  ExFiles\Box 164\5\  img263
Date  7th December 1936 guessed
  
TESTS SHEWING THE EFFECT OF SHORT CCT SECONDARY TURNS
TEST TAKEN WITH STD COIL & BALLAST
STD. DISTRIBUTOR .55 MAKE RATIO 12 VOLTS SUPPLY
H.T. OUTPUT TAKEN FROM DISTRIBUTOR

(A) COIL D.72503 WITHOUT SHORT CCT SECONDARY TURNS
(B) " " " WITH " " " "
(C) " " " WITHOUT " " " "
(D) " " " WITH " " " "

1 MEGOHM LOAD
1/2 MEGOHM LOAD

Vertical Axis: SECONDARY VOLTS (KILO-VOLTS)
Values: 12, 10, 8, 6, 4, 2, 0

Horizontal Axis: SPARKS/SEC.
Values: 0, 50, 100, 150, 200, 250

Top Right Corner: 25
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).


Copyright Sustain 2026, All Rights Reserved.    whatever is rightly done, however humble, is noble