Instructions regarding low-pressure loading and air leak settings on 40/50 HP rear hydraulic shock dampers.
| Identifier | ExFiles\Box 55\4\ Scan073 | |
| Date | 26th May 1927 | |
| To BY. {R.W. Bailey - Chief Engineer} from Hs {Lord Ernest Hives - Chair} /Rn. {Mr Robinson} x235 Hs {Lord Ernest Hives - Chair} /Rn {Mr Robinson} 3/LG26.5.27. 40/50 HP. REAR HYDRAULIC SHOCK DAMPERS. x235 x8520 We are anxious to keep the low pressure loading on the 40/50 HP. rear hydraulic shock damper at a minimum of 60 lbs. + 10 lbs. In order to ensure that the load does not fall below 60 lbs. will you pleasr instruct that this load should be obtained when the air leak is functioning (i.e. the .024" hole). At present we recommend that this hole should be temporarily blocked up until the load on the front damper has been checked. Hs {Lord Ernest Hives - Chair} /Rn. {Mr Robinson} | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).