Test report on Condenser No. 931 from Chassis No. GF.6.
| Identifier | ExFiles\Box 47\4\ Scan082 | |
| Date | 30th April 1924 | |
| EFC. {E. Fowler Clarke - Electrical Engineer} WA. {Mr Wallis} 27. 30.4.24. TEST OF CONDENSER No.931 EX CHASSIS No.GF.6. This condenser in the first place was tested to our standard production specification and was found to be as follows :- Test on 400 R.M.S. volts - O.K. Capacity at 21°C - .323 mf. Effect on contact breaker - O.K. points. No sparking. Capacity (warm 45°C) -.42 mf. Capability of holding a static charge also O.K. The condenser was then fitted to our standard battery ignition distributor and run under normal conditions (at 8 volts) for about 2 hours, the object of this test being for the purpose of enabling the fault to be reproduced. During the above test the condenser functioned satisfactorily, there being a minimum of flashing at the contact breaker points, and regular sparking (H.I.) on 6.5 mm. gaps. It is therefore considered from the results obtained that the condenser is quite O.K. EFC {E. Fowler Clarke - Electrical Engineer} /HEW. | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).