Log of battery charging and performance tests, detailing current, ampere-hours, cell densities, and temperature.

Identifier  ExFiles\Box 54\1\  Scan184
Date  8th July 1925
  
-3-

Date.

(13) Third charge equivalent to average current of 6.0 amperes for 17.0 hours.
i.e. ampere-hours = 102
30-6-25 to 1-7-25.

(14) Cell densities.
(1) 1280 (4) 1250
(2) 1250 (5) 1280
(3) 1280 (6) 1250
1-7-25.

(15) Initial amperes = 106 Temp :- 18.5 C 65 F
Ex - 1.55 voltages of each cell on discharge
Time to 104 amperes:- 3.6 mins.
per R 1.42 " " "
" " 100 " " 8.9 "
Ex 1.55 at approx.
" " 90 " " 13.9 "
per R 1.20 80 amperes.
" " 80 " " 16.3 "
Ex .85
per R. {Sir Henry Royce} 1.55
2-7-25.

(16) Fourth charge equivalent to average current of 6.0 amperes for 17.0 hours.
i.e. ampere-hours = 102.0
2-7-25 to 6-7-25

(17) Ampere hours realised up to a point where record takes a sudden turn down :- 58.3
Temperature :- 18 C. 64 F. {Mr Friese}
6-7-25

(18) Fifth charge equivalent to average current of 6.0 amperes for 17.0 hours
i.e. ampere-hours :- 102
7-7-25 to 8-7-25.
  
  