Performance analysis of a dynamo, comparing its characteristics to other models and detailing various output curves.

Identifier  ExFiles\Box 3\5\  05-page099
Date  22th February 1919
  
Contd.
-6-
EFC1/113.8.19.

It is a peculiarity of this machine that the open circuit voltage in the controlled condition is less than that in the plain shunt condition, which is not the case in the C.A.V. and Lucas dynamos. This is to be explained by the fact that in this scheme of control so much of the armature is short-circuited that the voltage is considerably reduced. There results from this, the fact that the cutting in point is later than as a shunt machine, and that the current delivered to a battery at speeds only just above the cutting in point is loss. But the rise of current with speed is so rapid that the characteristic curve crosses that for the simple shunt case and recrosses it again later, as seen on curves Z (Not yet taken).

Curves C shew the current speed characteristics of the machine when connected as a simple shunt wound dynamo. These are similar to those for Lucas K.575, but occur much earlier.

Curves D shew out-put speed curves with the machine correctly connected to 4, 5, 6, and 7 fully charged large capacity cells in series. It will be seen from these to what extent the ampere out-put of the dynamo increases with the voltage against which it is working. There are also plotted on this sheet, the field currents and control currents.

Curves E (which will be taken when time permits and sent later) will show the out-put speed curves with the machine arranged in various ways (a) (b) (c) (d) as below and set to charge a six well battery.

Contd.

GTCC(S) 745.2.200.-22.2.19.
  
  