From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Instruction to remount a C.A.V. voltage regulator from vertical to horizontal on the 4.Per.II chassis.
Identifier | ExFiles\Box 60\3\ Scan187 | |
Date | 23th February 1933 | |
86044 RHC.{R. H. Coverley - Production Engineer} From Hs{Lord Ernest Hives - Chair}/Wst. Hs{Lord Ernest Hives - Chair}/Wst.1/MA.23.2.33. C.A.V. VOLTAGE REGULATOR UNIT ON 4.Per.II. This unit has been mounted vertically on the dash on 4.Per.II and we are informed by the C.A.V. Co. that if their regulators are mounted vertically the whole adjustment is thrown out due to the vertical movement of the chassis. Will you please arrange to have this unit mounted horizontally on the above chassis. Hs{Lord Ernest Hives - Chair}/Wst. | ||