Observations and readjustment details for an automatic regulating switch's operating voltage under hot and cold conditions.

Identifier  ExFiles\Box 59\1\  Scan096
Date  8th November 1926
  
PC.119.

8.11.26.

AUTOMATIC REGULATING SWITCH.
(ORIGINAL UNIT)

As in the previous case, this unit was first adjusted to operate at 14.5 volts cold (18°C). When heated up on 17.0 volts, however, the operating voltage was found to be 16.5, instead of about 16.0.

It was therefore readjusted, while still in the hot condition, to operate at 16.2 volts, when the following observations were made:-

When heated up on 17.0 volts the switch
opens at 16.2 volts
closes at 11.7 "

When cold (18°C) it opens at 14.3 volts.

EFC/C.A.Pignatt.
  
  