Constructing a special thermo-couple with a cast iron element and testing its electromotive force.


Identifier  ExFiles\Box 76\3\  scan0130
Date  24th February 1926
  
X771

Hs {Lord Ernest Hives - Chair} /Mr.Robotham.

H15/EA24.2.26.

Laboratory.

Re Special Thermo-couple with one element of cast iron - for use at a maximum temperature of 700°C.

A couple suited to your purpose can be made with "Eureka" resistance wire, which can be obtained from the electricians' stores.
Tests carried out at a temperature of 750°C with a couple 15" long made from 18 gauge wire spot welded to a 5/16" rod of cast iron gave an E.M.F. of 38 millivolts.

H1/EJW

[Signature EJW]
  
  