Continuation of testing procedures for a relay switch unit, including spring tension and voltage breakdown tests.

Identifier  ExFiles\Box 70\4\  scan0141
Date  5th March 1925
  
contd : -4- EFC4/E5.3.25.
----------
X8781 ms

(5) Now verify that the main spring tension (combined rating and set) is such that with a current of 3.0 amperes passing through the fine winding, a load of at least 3.0 lbs. measured at the core on a spring balance is required to break contact of the lower contacts.

(6) Whilst still warm from test (5) an alternating voltage of 205 shall be applied, through a lamp, between the windings (both) and the base, for one minute without break-down.

(7) The final test of this relay switch unit is to consist of testing under approximate operating conditions as described in Section III.

EFC.