Table showing the results of cooling tests carried out on chassis 1 B IV at Brooklands.

Identifier  ExFiles\Box 131\5\  scan0004
Date  3rd November 1937 guessed
  
RESULTS OF COOLING TESTS CARRIED OUT ON 1 B IV AT BROOKLANDS.

TABLE DATA:

HEADERS:
CONDITIONS, SIZE OF BYPASS, TOP WATER TEMP °C, BOTTOM WATER TEMP °C, AIR TEMP °C, WATER PRESS IN THERMOSTAT CASING LBS D", MAX. WATER PRESS WHEN COLD WITH THERMOSTAT WORKING LBS. D", CRITICAL AIR TEMP (UNCORRECTED), CRITICAL AIR TEMP (CORRECTED)

ROW 1:
Condition: MAX. SPEED FULL THROTTLE (30 M.P.H.)
Size of Bypass: 7/16" DIA.
Top Water Temp °C: 70
Bottom Water Temp °C: 57
Air Temp °C: 15
Water Press in Thermostat Casing: 4.0 LBS D"
Max. Water Press When Cold: 20 LBS. D"
Critical Air Temp (Uncorrected): 45
Critical Air Temp (Corrected): 47.3

ROW 2:
Condition: THERMOSTAT VALVE FULL OPEN FOR CRITICAL AIR TESTS
Size of Bypass: 1/2" DIA.
Top Water Temp °C: 73
Bottom Water Temp °C: 59
Air Temp °C: 15
Water Press in Thermostat Casing: 3.5 LBS D"
Max. Water Press When Cold: 25 LBS. D"
Critical Air Temp (Uncorrected): 42
Critical Air Temp (Corrected): 40.6

ROW 3:
Condition: THERMOSTAT VALVE FULL OPEN FOR CRITICAL AIR TESTS
Size of Bypass: 5/8" DIA.
Top Water Temp °C: 75
Bottom Water Temp °C: 59
Air Temp °C: 15
Water Press in Thermostat Casing: 3.0 LBS D"
Max. Water Press When Cold: 33 LBS. D"
Critical Air Temp (Uncorrected): 40
Critical Air Temp (Corrected): 38.5

ROW 4:
Condition: 30 M.P.H. FULL THROTTLE
Size of Bypass: 7/16" DIA.
Top Water Temp °C: 73
Bottom Water Temp °C: 60
Air Temp °C: 13.5
Water Press in Thermostat Casing: 2.0 LBS D"
Max. Water Press When Cold: —
Critical Air Temp (Uncorrected): 40.5
Critical Air Temp (Corrected): 39.2

ROW 5:
Condition: THERMOSTAT VALVE FULL OPEN FOR CRITICAL AIR TESTS
Size of Bypass: 1/2" DIA.
Top Water Temp °C: 73
Bottom Water Temp °C: 58.5
Air Temp °C: 12.5
Water Press in Thermostat Casing: 2.0 LBS D"
Max. Water Press When Cold: —
Critical Air Temp (Uncorrected): 39.5
Critical Air Temp (Corrected): 38.0

ROW 6:
Condition: THERMOSTAT VALVE FULL OPEN FOR CRITICAL AIR TESTS
Size of Bypass: 5/8" DIA.
Top Water Temp °C: 73.5
Bottom Water Temp °C: 57.5
Air Temp °C: 12.0
Water Press in Thermostat Casing: 2.0 LBS D"
Max. Water Press When Cold: —
Critical Air Temp (Uncorrected): 38.5
Critical Air Temp (Corrected): 37.0
  
  