Laboratory advice note detailing the output figures for LRT7 Regulators under various conditions.
| Identifier | ExFiles\Box 166\2\ img117 | |
| Date | 30th September 1937 | |
| RR LABORATORY ADVICE NOTE. No. 3355. Mr.Toulmin. To:- Technical Sales Dept. Date:- 30th September,1937. EL/CER/S. Please receive, herewith For Rolls Royce. 2 - LRT7 Regulators for Messrs.Rolls-Royce Ltd. The regulator setting at 20°C. is 16.8v. and the cut-out setting 13.0v. The output figures on resistance load are as follows:- Output cold at 13 volts = 16.5 amps. Output at 13v. after running on 14 amp. load for 1 hr. with cover off = 16.6 amps. Output at 13v. after running on 14 a. {Mr Adams} load for 1 hour with cover on = 15.6 amps. When run with a battery and a 13 a. {Mr Adams} lamp load the output figures are as follows:- Output, cold, at 13 volts = 20 amps. Output at 13 volts after running on 14a. load for 1 hr - cover off = 21 amps. ditto, cover on = 19.1 amps. Each unit is fitted with a thermostatically compensated cut-out. The cut-in voltage falls to 12.8 volts when the regulator is run on 14 a. {Mr Adams} load for 1 hr. with the cover on. ---- E. {Mr Elliott - Chief Engineer} Lloyd. FORM NO.LAB/1. | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).