Test results comparing a standard radiator with a radiator fitted with copper tubes.


Identifier  ExFiles\Box 38\2\  Scan169
Date  13th January 1922
  
Mr. Hives from GWH. {George W. Hancock - Head Chateauroux}
X3456
13.1.22.
TESTS WITH STANDARD RADIATOR AND RADIATOR WITH COPPER TUBES.
Standard.
M.P.H. | Start | 1/2 mile | 1 mile | 1 1/2 mile | 2 miles | 2 1/2 miles | 3 miles
30 | 130°F | 132° | 132° | 130° | 130° | 130° | 130°
30 | 130°F | 130° | 130° | 130° | 130° | 130° | 131°
Copper tubes.
30 | 130°F | 132° | 134° | 135° | 136° | 136° | 136°
30 | 130°F | 131° | 133° | 136° | 137° | 137° | 138°
Test taken on London Rd. - temp. of atmosphere 5°C.
Tests taken under same conditions.
GWH. {George W. Hancock - Head Chateauroux}
  
  