Output tests on coils.


Identifier  ExFiles\Box 164\5\  img385
Date  8th August 1938
  
OUTPUT TESTS ON COILS.
MAKER: Delco-Remy
TYPE: High Output 16A.
DISTRIBUTOR USED: Delco-Remy
MAKE RATIO: .75
LOAD VALUE: .5 Megohms
VOLTAGE: 12.0
AMBIENT TEMPERATURE: 24°C
DATE: 8-8-38
CONDITIONS OF TEST:
Coil reported faulty off 29GVI.
Output taken through distributor with the coil in a cold condition.
DIST. SPEED | GAP. | KILO-VOLTS | PRIMARY CURRENT
0 | | | 3.95
200 | .047 | 5.7 | 2.5
400 | .053 | 6.2 | 2.13
600 | .059 | 6.8 | 2.00
800 | .059 | 6.8 | 1.91
1000 | .061 | 7.0 | 1.78
1200 | .061 | 7.0 | 1.66
1400 | .060 | 6.9 | 1.59
1600 | .060 | 6.9 | 1.51
1800 | .060 | 6.9 | 1.41
2000 | .059 | 6.8 | 1.32
2200 | .058 | 6.7 | 1.16
2400 | .056 | 6.5 | 1.05
Primary Inductance:-
Secondary Inductance:-
Tested By:
  
  