Specification sheet for a Wave Analyser, Type TF.455.


Identifier  ExFiles\Box 138\1\  scan0306
Date  1st January 1938 guessed
  
3.

SPECIFICATION
OF
WAVE ANALYSER.
TYPE TF. {T. Fisher} 455.

FREQUENCY RANGE 20 - 15,000 c.p.s.
FREQUENCY CALIBRATION ±2% ±10c.p.s.
SELECTIVITY The response is down 6 dB {Donald Bastow - Suspensions} at 2 c.p.s; 40 dB {Donald Bastow - Suspensions} at 30 c.p.s. and 60 dB {Donald Bastow - Suspensions} at 90 c.p.s. The selectivity is constant throughout the whole operating frequency range.
VOLTAGE RANGE 0.2 millivolts to 200 volts.
VOLTAGE ACCURACY ±5% except below 2 mV where the accuracy falls to ±10%.
INPUT IMPEDANCE 10,000 ohms.
CALIBRATION Means are provided for standardising the calibration at power supply frequencies.
POWER SUPPLY Unspillable 2 volt accumulator and 135 volt dry battery.
MOUNTING All controls are conveniently disposed on a vertical aluminium panel. The chassis and screens are built on this panel, the whole unit being mounted in a steel case with protective panel bars and twin carrying handles.
FINISH Panel: Black crackle lacquer. Case: Grey cellulose enamel.
DIMENSIONS 29" long x 16" high x 12" deep (over projections).
WEIGHT 35-lbs. (complete with batteries)
PRICE See Price Index.
  
  