Technical data table comparing performance characteristics of Remy 12, Remy 6, and Delco contact breakers.

Identifier  ExFiles\Box 52\3\  Scan271
Date  28th April 1917 guessed
  
-4-

Remy 12. Remy 6. Delco

CONTACT BREAKER.
No. of breaks per revolution 12 6 6
Platinum gap set at .020" .028" -
Ratio Time contact made / total time .670 .65 -
(Period (sec) .00556 .01111 -
(Time of make (sec) .00372 .0072 -
(Time of break (sec) .00184 .0039 -
All at 900 R.P.M. of breaker.

CONTACT BREAKER & PRIMARY.
Ratio time of make / time constant 1.145 1.09
Calculated current at break (amperes) 4.42 3.5
Both at 900 R.P.M. of breaker.

CONTACT BREAKER & CORE.
Approx. flux at break 7880 10400

CONTACT BREAKER PRIMARY & CORE.
Approx. flux interlinkages at break. 1,326,000 12,620,000

CONTACT BREAKER SECONDARY & CORE.
Approx. flux interlinkages at break. 180.8 158 / 167 x 10^6
Approx. quantity of electricity discharged per break (microcoulombs). 441 575

C' / Co .682 .665
  
  