Rolls-Royce Archives
         « Prev  Box Series  Next »        

Representative performance figures and routine procedure for the New Standard 20 HP Dynamo.


Identifier  ExFiles\Box 165\6\  img003
Date  29th September 1924
  
X5660

EFC {E. Fowler Clarke - Electrical Engineer} /T29.9.24.

REPRESENTATIVE PERFORMANCE FIGURES. (57 CCM. SECS.)
NEW STANDARD 20 HP. DYNAMO ROUTINE PROCEDURE.

(1) Cold balancing speed for 12.4 volts at 575 r.p.m. 10 volts at 505 r.p.m. and 17 volts at 715 r.p.m. S
(2) No amperes at balancing speed as above, 8 amperes (14.0 volts) at 790 r.p.m., 14 amperes (15.2 volts) at 970 r.p.m. S
(3) Angular position of control brush 120° from positive brush. Maximum ampere output as in (5) below. C
(4) Hot balancing speed for 13.6 volts at 680 r.p.m. 10 volts at 595 r.p.m. and 17 volts at 770 r.p.m. C
(5) Balancing speed as in (4). Maximum amperes 11.0 at 1610 r.p.m. C
(6) Hot balancing speed for 13.6 volts at 665 r.p.m. 10 volts at 560 r.p.m. and 17 volts at 770 r.p.m. S
(7) Balancing speed as in (6), 8 amperes at 925 r.p.m. 14 amperes at 1190 r.p.m. S
(8) Cold balancing speed for 12.4 volts at 585 r.p.m. 10 volts at 520 r.p.m. and 17 volts at 705 r.p.m. C
(9) Balancing speed as in (8) above. Maximum amperes 13.5 at 1510 r.p.m. C
(10) Hot balancing speed for 13.6 volts at 700 r.p.m. Maximum amperes 10.0 at 1625 r.p.m.

EFC. {E. Fowler Clarke - Electrical Engineer}
  
  
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).