Comparative test results for a reduced volume Enot's petrol filter.


Identifier  ExFiles\Box 106\2\  scan0103
Date  8th August 1932
  
X5460.

X4037.
X5460.

REDUCED VOLUME ENOT'S PETROL FILTER. 8.8.32.

This filter specially supplied by Enot's, had a petrol volume of 30 ccs. as against the standard volume of 80 ccs.

When tested in conjunction with an LeC.2961 petrol pump having .250" stroke, and ¼" dia. suction pipes, the following comparative results were obtained.

| | Secs. Initial pumping time | Delivery pts/hr at 1750 prpm. |
| | 20 prpm. | 50 prpm. | 75 prpm. | |
|------------------------------------------|----------|----------|----------|------------|
| Suction Pipe connected direct to pump. | 61 | 33 | 18 | 109 |
| Special Enot's 30 cc filter. | 80 | 45 | 27 | 102 |
| Standard 80 cc. filter. | 107 | 53 | 27 | 100 |
  
  