Rolls-Royce Archives
         « Prev  Box Series  Next »        

From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Comparison of various battery types, detailing their discharge curves, capacity results and weights.

Identifier  ExFiles\Box 54\2\  Scan047
Date  17th October 1924
  
Contd. -9-7 EFCL/T17.10.24.

more particularly with the Exide 6EXRE5 batteries, and either
of the two should give excellent service.

They are precisely in accordance with our
up-to-date specification No.301, copy of which we attach
hereto.

Typical high rate discharge curves of the
various batteries mentioned above are given on photostat copy
of sheet T herewith.

The curve of the P & R RR.LL/1 battery does not
appear as good as that for the Exide 6.RRS/1/2. This is
because these curves are taken early in the life of the
batteries and it is known from experience with other P & R
batteries that the P & R curve will increase progressively
for a time, whilst it is not anticipated that the Exide will.

Typical low rate discharge capacity results of
actual discharge through a constant external resistance of
1.17 Ohm are as follows :-

Exide 6DXRE5. 58 ampere-hours. Weight 83 lbs.
Exide 6EXRe/SPL. 57 " " 88 lbs.
P & R BDT.11. 46.0 amp.hours initially,i
increasing to 57.0 amp.hours." 95 lbs.
Accu-Slem. 52.0 ampere-hours after con-
siderable use. Weight 86 lbs.
Lithanode. 46 ampere-hours initially, 92 lbs.
with a tendency to increase.
Fuller Sparta.. .. 109 ampere-hours. " 103&1/2lbs.
Exide 6RRS/1 51 " " 103 lbs.
P & R RR.11. 53 amp.hours initially
with a tendency to increase. " 103 lbs

Contd.
  
  