Page from a test procedure detailing electrical and physical inspection steps.

Identifier  ExFiles\Box 163\6\  img271
Date  27th February 1933 guessed
  
-2-

These readings should lie between the limits 1.20 and 1.25 volts and 4.87 and 4.97 volts respectively.

(3) The current should then be raised to 2.0 amperes at which value it should be maintained for 5 minutes.

(4) At the end of the above test examine the ends of the wire where they pass under the rivets and ascertain that they are sound. The porcelain holder should also be examined for cracks, and the rivets for looseness.
  
  