Radiator tests at Brooklands for Chassis No. 22-G-V.
| Identifier | ExFiles\Box 103\4\ scan0168 | |
| Date | 31th March 1936 | |
| Chassis No. 22-G-V. {VIENNA} Radiator Tests at Brooklands. (1) Header tank half full. Max speed, full throttle. Air temperature 14°C. Head wind on Railway Straight. Following wind past Vickers Shed. Water Temp. in Engine. Water Temp. in Rad. Difference. 81°C. 75°C. 6°C. 87 80 7 88 80 8 82 75 7 85 80 5 85 78 7 Average 84.6°C. 78°C. Mean diff. 6.6°C. (2) Header tank empty. (Matrix just covered) Conditions as above. Mirror fitted to observe shutters. Water Temp. in Engine. Water Temp. in Rad. Difference. Shutter Position. 76°C. 72°C. 4°C. Half open. 90 1/2 80 10 Open. 83 75 8 Half open. 79 71 8 Half open. 83 75 8 Half open. 85 80 5 Half open. 89 81 8 Open. 83 75 8 Open. 80 72 8 Half open. 81 72 9 3/4 open. 80 75 5 Half open. 82 77 5 Half open. (Slowed down) 82 75 7 Open. Average 83°C. 75.4°C. 7.6°C. (3) Same conditions as (2), but at reduced speed. Water in Engine. Water in Rad. Difference. Shutter Position. 75°C. 65°C. 10°C. Half open. 79 70 9 Half open. 77 69 8 Half open. (Speed increased) 86 80 6 Half open. 80 71 9 Half open. Average 79.4°C. 71°C. 8.4°C. | ||