Data table of temperature and time readings from a series of cooling system tests under different configurations.


Identifier  ExFiles\Box 75\4\  scan0065
Date  17th August 1911
  
R.R. 148 (20 H) (W 730. 17.8.11) C
X819

Atmos. Water Flowboards Time Conditions
Temp. Temp. Top Under

21°c | 75° | 30 | 42 | 0
21°c | boiled | 28 | 48 | 5 | Both side guards closed, standard bonnet no dash screen.

25°c | 75° | 30 | 46 | 0
22°c | boiled | 30 | 50 | 7 | Both side guards closed Louvred bonnet no dash screen.

21°c | 75° | 24 | 30 | 0
21°c | boiled | 25 | 34 | 5 | Dash screen in side guards closed, louvred bonnet.

21°c | 75° | 24 | 34 | 0
21°c | boiled | 25 ½ | 37 ½ | 6 | Dash screen in, louvred bonnet; side guards open.

16°c | 75° | 18 | 22 | 0
16°c | boiled | 18 | 27 | 5 ½ | Dash screen in, standard bonnet side guards open.
  
  