Comparative heating tests and weights of various shunt-wound dynamos.


Identifier  WestWitteringFiles\F\January1921\  Scan21
Date  30th December 1920
  
R.R.285a (100 T) (S.H 159, 11-8-20) G. {Mr Griffiths - Chief Accountant / Mr Gnapp} 2800

X.294. COMPARATIVE HEATING TESTS OF SHUNT-WOUND DYNAMOS AT CONSTANT OUTPUT.

TABLE OF FINAL CONDITIONS.
(After 3 or 4 hours running)

Out-put

[Test 1] 9 amps. at 14.6 volts.
[Test 2] After 3 or 4 hours running. 12 amps. at 15.0 volts.

Dynamo. Temp of carcase (°C). Temp. by field winding resistance. (°C). Speed R.P.M. Temp. of carcase (°C). Temp by field winding resistance (°C). Speed R.P.M.
Smith A. {Mr Adams} 94 128 950 -- -- --
Smith 2D. 88 118 835 -- -- --
Westinghouse. 53 67 765 62 84 885
Bosch. 80 120 640 100 152 680
Bijur. 52 67 790 64 84 880

WEIGHTS.
Smith "A" - 32 lbs.
Smith "2d" - 32.6 lbs.
Bijur - 30.5 lbs.
Bosch - 37.0 lbs.
Rotax - 27.0 lbs.
U.S.A. Bosch - 21.1 lbs.
Westinghouse - 30.7 lbs.

EFC. {E. Fowler Clarke - Electrical Engineer}
  
  