The results of heating tests on 'Bakelogue' material regarding leakage and breakdown.
| Identifier | ExFiles\Box 39\3\ Scan310 | |
| Date | 1st December 1924 guessed | |
| RR 238 (150 BKS.) 100 461-8 12 24) MP 306975 ROLLS-ROYCE LTD. INSTRUCTIONS. To_____________________________________19 Order No________________ Customer's No. / In all cases there was some improvement after heating; some pieces actually improved whilst rising from 80° to 100°. Probably further improvement would take place with prolonged heating as has been found to be the case with moulded articles. There seems to be considerable disparity in the results obtained with two similar samples (second and third cases above) and this may be due to varying degrees of 'curing' which they have been given. The above results however sufficiently show the 'Bakelogue' to be not inferior to the standard material as regards leakage. The breakdown test, next carried out gave results as follow — Signed__________________(Cont'd) This Sheet must be filed on completion of the work. | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).