Design critique of a hydraulic damper control connection, noting a fault causing oil loss and suggesting a design improvement.


Identifier  ExFiles\Box 11\5\  05-page007
Date  10th April 1934 guessed
  
X7941
Hydraulic Damper
YES
28EX
We would like to point out the faulty feature in the design of the control connection on the damper. This is made by a separate elbow screwed into the valve head of the damper and as to be at a correct angle to join up to the pipe line this has to be got by varying thickness of aluminum washer - help the production. It works loose and consequent loss of oil from the control system. Why cannot this union be cast with the valve control member saving money, time, and depot work.
Breather
This is designed wrongly.
We will later send something better.
F.H.Hescock
  
  