Rolls-Royce Archives
         « Prev  Box Series  Next »        

Calculation sheet for the electrical characteristics of a condenser and transformer system.


Identifier  ExFiles\Box 52\3\  Scan365
Date  14th February 1924 guessed
  
-4-

CONDENSER.
Capacity (microfarads) K 900-.465

PRIMARY & CONDENSER.
Period of oscillatory current (secs) T = 2π√LK {L. King} .000234
Radio wave length (metres) VT 70200

PRIMARY, CONDENSER & BALLAST
Decrement of oscillatory current πR√(K {Mr Kilner} /L) .0361
Damping factor. .9645
Ratio working time constant / period t₁/T 13.9
Maximum voltage c'√(L/K) 355

SECONDARY.
Number of turns. n 25870
Dia. of wire (inches) .005
Approx. resistance (ohms) R' 4100
" inductance (henries) L' 62.0
" time constant (sec) L'/R' .01513
Maximum voltage MC'/√LK {L. King} 48400

PRIMARY & SECONDARY.
Step up ratio n'/n 143.7
Coefficient of coupling assumed η' .949
(η = η'² = )
Mutual inductance. M = η'√(LL') .409
LL' - M² .0186.

Contd.
  
  