Test procedures for an electrical switch, specifying contact pressure and voltage tolerance.


Identifier  ExFiles\Box 168a\2\  img155
Date  17th April 1935 guessed
  
-3-

should break reasonably sparklessly.
(3) It should now be confirmed by means of a spring balance that the switch is definitely capable of holding on contact with a copper contact pressure of 2.0 lbs. measured by hooking a spring balance to the lever when a current not exceeding 3.4 amperes, inclusive of the current passing through the parallel non-inductive resistance, is supplied to it.
(5) Whilst still warm from above test, an alternating voltage of 200 shall be applied, through a lamp, between the windings including the non-inductive resistance coil, and the switch arm; and also between the main switch contact pillar and the switch arm; for one minute without breakdown.

Ha/Wst.
  
  