Rolls-Royce Archives
         « Prev  Box Series  Next »        

From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).
Formulae and example calculations for determining bonnet temperature using bypass control and shutter methods.

Identifier  ExFiles\Box 87\5\  scan0158
Date  21th September 1934
  
-2-
Ha/Std.7/KW.21.9.34.

Let B1 = temp. of air after passing through matrix, with atmospheric temp. of T1
B2 = temp. of air after passing through matrix with atmospheric temp. of T2
M = mean water temp. in radiator, with shutters in operation

} All temps. in oC. absolute.

Formulae for determination of bonnet temp. B2

(a) Bypass Control.
B2 = B1 + T2 - T1 - (B1 - T1)(1 - T2/T1)

(b) Shutter Method.
B2 = T2 + (M - T2)/(M - T1) (B1 - T1)

Taking figures obtained at Brooklands (30 M.P.H.), with an air temp. of 20oC, bonnet temps. were respectively (a) 32.0oC. (b) 39.0oC. Mean water temp. = 70oC.

With an air temp. of 0oC, these become
(a) 10.9oC.
(b) 26.6oC.

Hs{Lord Ernest Hives - Chair}/Std.
  
  


Copyright Sustain 2025, All Rights Reserved.    whatever is rightly done, however humble, is noble
An unhandled error has occurred. Reload 🗙