Performance chart for a Vauxhall 14 HP radiator, showing horsepower dissipated and air pressure against air flow.


Identifier  ExFiles\Box 149a\2\  scan0276
Date  6th November 1935 guessed
  
CHART No. L | 592 B
VAUXHALL 14 H.P. RADIATOR
FRONTAL AREA = 1.6 sq. ft.
COOLING SURFACE = 28.5 sq. ft.
FT. RUN TUBING =
WT. OF TUBING = LBS
WATER VELOCITY = FT. SECOND
AIR INLET 60 °F
WATER MEAN 160 °F
TUBE TYPE
DEPTH OF BLOCK = 2 3/32"
COPPER USED FOR CONSTRUCTION OF WATER PASSAGES & JOINING STRIP
ALL EXPOSED SURFACES TINNED
WIDTH OF WATER PASSAGE = 1 1/4"
12.5 GALS. MIN. FT. OF WIDTH
SECTION THRO' ELEMENT
(WATER PASSAGES SHADED)
COLD AIR PRESSURE INCHES OF WATER
ELEMENT TRUNKED FORE & AFT.
H.P. DISSIPATED
AIR PRESSURE
AIR FLOW CUBIC FT. MIN. / SQ. FT. FRONTAL AREA
HORSE POWER DISSIPATED @ 100°F DIFFERENCE / SQ. FT. FRONTAL AREA
STAMP: CLAYTON DEWANDRE CO. LTD. TITANIC WORKS LINCOLN
  
  