Graph of water flow tests on a PII No 7 unit with a standard radiator.


Identifier  ExFiles\Box 15\1\  Scan407
Date  14th October 1930 guessed
  
WATER FLOWS TESTS ON PII N° 7 UNIT.
STANDARD RADIATOR (E. {Mr Elliott - Chief Engineer} 77675) OFF PRODUCTION
STANDARD CIRCULATION
DELIVERY GALLS/MIN.
PRESSURE LBS/SQ"
DEPN LBS/SQ"
LBS/SQ" PRESSURE
DELIVERY SIDE PUMP
BOTTOM WATER TEMP.
LBS/SQ" DEPRESSION
SUCTION SIDE PUMP.
LEGEND:
2500 R.P.M.
3000 R.P.M.
CIRCULATION UNDER 4 LBS/SQ" PRESSURE.
R.P.M.
2500
3000
  
  