Comparison graph of seamed tube oval flattened wire radiator elements, plotting HP dissipated and air pressure against air velocity.
| Identifier | ExFiles\Box 131\1\ scan0232 | |
| Date | 28th February 1936 | |
| L604D COMPARISON OF SEAMED TUBE OVAL FLATTENED WIRE ELEMENTS ALL ELEMENTS REDUCED TO 1·14" DEEP AND 14·4 GALLS./MIN./FT. OF WIDTH. LENGTH OF FLAT. ANGLE OF FLAT. 452 7" 22G. WIRE 8 WIRES DEEP 13·82 WIRES/" HEIGHT .009" CU. TUBE 18·6/FT WIDTH. WIRE WT. 2·52 LBS. L581 452 7° 22G 8 10·1 .009" 18·5/- 1·85 L585 483 0° 22G " 12·9 " 17·8 1·268 L600 495 0° 22G " 8·9 " 17·95 ·885 L603 493 0° 22G " 16·3 " 18·05 1·582 L604 483 7° 22G " 12·9 " 18·0 1·268 L605 495 0° 21G 8 .009" L60630 HARRISON L 608 MARSTON MARK VI L 609 MARSTON MARK V L 610 GALLAY L 611 FRONTAL AREA = 1 ☐' AIR IN 60°F MEAN WATER TEMP. 160°F. {Mr Friese} STATIC COLD AIR PRESS. INS. WATER HP. DISSIPATED AIR FACE VELOCITY. FT/MIN. AT 60°F Graph Labels: 611, 608, 609, 610, 604, 581, 600, 603, 605, MORRIS, 585. Vertical Text: NOV 1935 E.W.S 28/2/36 | ||
From the Rolls-Royce experimental archive: a quarter of a million communications from Rolls-Royce, 1906 to 1960's. Documents from the Sir Henry Royce Memorial Foundation (SHRMF).