Test results from intensive heating, preliminary breakdown, and primary current consumption tests on an electrical component.


Identifier  ExFiles\Box 164\5\  img007
Date  27th January 1931 guessed
  
-3-

(6) Intensive heating tests.

(a) Secondary resistance after test :- 5900 ohms.
Corresponding temperature :- 180 °C.
Primary current at end of test :- 1.12 amperes.
Ambient temperature :- 17.5 °C.

Handwritten text on left:
6 hours running at 700 r.p.m on 17.5 volts in a temp. of 80°C
Make ratio .70.

(b) Secondary resistance after test :- 5800 ohms.
Corresponding temperature :- 172 °C.
Primary current at end of test :- 1.800 amperes.
Ambient temperature :- 15 °C.

Handwritten text in middle:
When coil is hot as above no sparks can be obtained on 5.5 mm three point gaps. This constitutes a failure.

(7) Preliminary breakdown test.
Test voltage on secondary =

(8) Primary current consumption.

speed. Current (amperes)
200
300
400
500
600
700
800
1000
1200
1400
1600
1800
  
  