Rolls-Royce Archives
         « Prev  Box Series  Next »        

Test report on a Dayton Cog VC 17 belt, detailing measurements and test termination.


Identifier  ExFiles\Box 135\1\  scan0204
Date  22th September 1938
  
22nd September, 1938.

Dayton Cog VC 17

Lab.Ref.8448

Pulley diameter 3-21/32"
" angle 33°56'

Belt Periphery - external
start 42-13/16
end -

Belt Periphery - internal
start 38-5/8
end -

Initial centres - 12.7

Fan speed - 4000 - 4360
Driven speed - 4100 - 4480

% Slip Initial 4.4
Average 7
Minimum 1.8
Maximum 9.8

H.P. 2nd fan - 24
3rd " - 28

V centres adjusted 5 times to maximum V centre
possible = 13.7" = 2"elongation

Test stopped because excessive slip and all
adjustment used, after 6 hrs.

[Signature]
  
  