REMY 12. REMY 6. DELCO

CONTACT BREAKER.
No. of breaks per revolution. 12 6 6
Platinum gaps set at .020" .028" -
Ratio time contact made / total time .67 .65 -
Period (sec) .00556 .01111 -
Time of make (sec) .00372 .0072 -
Time of break (sec) .00184 .0039 -
All at 900 R.P.M. of breaker.

CONTACT BREAKER & PRIMARY
Ratio time of make / time constant 1.145 1.09
Energy delivered by battery per period (joules) .0587 .087
Calculated current at break (amperes) 4.42 3.50
Ratio current at break / final current .682 .665
All at 900 R.P.M. of breaker.

CONTACT BREAKER & CORE
Approx. fluxat break. 7380 7400 10400

CONTACT BREAKER PRIMARY & CORE
Approx. flux interlinkages at break. 1,325,000 2,620,000
Energy of magnetic field at break (joules) .0293 .046
Approx. efficiency of magnetic field production. .50 .53

CONTACT BREAKER SECONDARY & CORE
Approx. flux interlinkages at break. 180.8 192 x 10^6 157 167 x 10^6
Approx. max. quantity of electricity discharged per break (microcoulombs) (arc component on indef: small gap). 441 470 575 610
  
  